BioXen — Research CompoundsBioXen — Research Compounds
  • Shop
  • Blends
  • Lab Supplies
  • Research
  • About
  • Contact
  • Contact us
BioXen — Research Compounds

Explore the range

  • Research compounds
  • Compound blends
  • Laboratory solutions
  • Laboratory supplies

Discover

  • Research library
  • About us
  • Contact

Support

  • Shipping Policy
  • Returns & Refunds
  • Privacy Policy
  • Terms & Conditions
  • Cookie Policy
  • [email protected]

For laboratory research

  • Research compounds and laboratory essentials.
  • Not for human or veterinary use.

For laboratory research use only. Not for human consumption. Must be 18 or older to purchase.

Company Reg: 15782804© 2026 BioXen Research. All rights reserved.

Your privacy

Cookie Settings

Choose which optional cookies you allow. Essential storage stays on so the website can work.

Your basket

Loading your basket…

BioXen — Research Compounds

For research use only

Age verification required

You must be 18 years or older to access this website. Our products are intended for research purposes only.

By entering, you confirm that you are of legal age in your jurisdiction and that any products purchased are for research purposes only.

Privacy Policy · Cookie Policy

Home/Research library/Understanding a Certificate of Analysis

Understanding documentation

Understanding a Certificate of Analysis

How to read a peptide certificate of analysis: identity by mass spectrometry, HPLC purity, measured content, and how to match a report to the batch in your vial.

Published 13 October 2026 · 9 min read

On this page

What is a certificate of analysis?The fields you will seeIdentity: is it the right molecule?Purity: what an HPLC percentage meansContent: how much is actually there?Blends need a result per componentMatching a report to your vialTested samples and batch reportsWarning signsCommon questions

More from the library

Comparing individual compounds and blendsWhat to look for on a research-product page

BioXen supplies materials for laboratory research only. Nothing in this library is medical advice or guidance on use in people or animals.

In short

  • A certificate of analysis (COA) is a laboratory's record of what it measured in one specific sample. It answers three questions: is this the right molecule, how pure is it, and how much is there.
  • Identity comes from mass spectrometry. The observed molecular mass should match the theoretical mass of the named compound.
  • HPLC purity is a percentage of the UV-detectable material in the sample. It does not count water, salts or counter-ions, so 99% purity does not mean 99% of the vial weight is peptide.
  • Measured content is a separate figure, in milligrams. A report can state purity without stating content.
  • A report only describes your vial if the batch reference, product and vial size match the label.

What is a certificate of analysis?

A certificate of analysis, usually shortened to COA, is the written result of laboratory testing on one sample of material. For a research peptide it records which tests were run, which methods the laboratory used and what the numbers came out at.

A COA is evidence about a sample. It says nothing about any other batch, and it carries the same weight as the laboratory that produced it. Read it with both points in mind.

The fields you will see

Most peptide reports contain the same core fields, even when the layout differs between laboratories.

FieldWhat it tells youWhat to check
LaboratoryWho ran the testsA named, contactable laboratory, not just a logo
Report or task numberThe laboratory's own reference for the jobPresent, and usable for verification where the laboratory offers it
Batch or lot referenceWhich production batch the sample came fromMatches the batch printed on your vial
Sample descriptionWhat was submitted, including the stated strengthSame compound and vial size as your product
Test dateWhen the analysis happenedA plausible date relative to the batch
IdentityWhether the molecule is what the label saysObserved mass agrees with the theoretical mass
PurityShare of the detectable material that is the target compoundStated as a percentage with the method named
ContentHow many milligrams were measuredClose to the stated vial strength

Identity: is it the right molecule?

Identity testing confirms that the sample contains the named compound. Laboratories normally use mass spectrometry (MS), often coupled to liquid chromatography (LC-MS).

The instrument measures the mass of the molecules in the sample. The report compares the observed mass with the theoretical mass, which is calculated from the compound's sequence. BPC-157, for example, is a 15-residue peptide with the formula C62H98N16O22 and a molecular weight of about 1419.5 g/mol. An identity result for BPC-157 should land on that figure within the instrument's tolerance.

Peptides with several charges can appear as more than one peak, so a report may list the expected mass-to-charge (m/z) values instead of a single mass. A competent report still states which compound the result confirms.

Purity: what an HPLC percentage means

Purity is usually measured by high-performance liquid chromatography (HPLC) with UV detection. The sample is separated in a column, and a detector records each component as a peak as it leaves. Purity is the area of the target peak as a percentage of the total area of all detected peaks.

That definition has a limit that catches many readers out. HPLC-UV only sees material that absorbs UV light at the chosen wavelength. Water, inorganic salts and counter-ions left over from synthesis, such as acetate or trifluoroacetate (TFA), are largely invisible to it. A peptide can show 99% HPLC purity while a meaningful share of the powder's weight is not peptide at all.

So purity answers one question: of the peptide-related material present, how much is the correct sequence? It does not answer how much peptide is in the vial.

Content: how much is actually there?

Measured content, sometimes called quantity or net peptide content, is the figure in milligrams. Laboratories derive it by comparing the sample's response with a calibrated reference, or by methods such as amino acid analysis.

Content and purity are independent. A vial can be very pure but under-filled, or correctly filled with a less pure product. That is why a report showing purity alone leaves a question open, and why BioXen product pages show "Not reported by this test" when a laboratory did not measure one of these values, instead of leaving the field out.

Expect some variation between the stated strength and the measured content. Weighing small quantities of lyophilised powder and quantifying them both carry tolerances. A result far below the label is a different matter.

Blends need a result per component

A blend vial holds two or more compounds. A single purity or content figure for the whole vial says little about each ingredient. A useful blend report gives a separate result for every component, so you can compare each one with the quantity declared on the label. Our guide to comparing individual compounds and blends covers this in more detail.

Matching a report to your vial

A report describes your material only if it describes your batch. Check these in order:

  1. The product name on the report is the compound on your label.
  2. The stated strength (for example 10 mg) matches your vial size.
  3. The batch or lot reference on the report matches the one on your vial.
  4. The test date makes sense for that batch.
  5. The laboratory can confirm the report, where it offers verification.

If any of the first three fail, the report is about different material. It may still say something about a supplier's general quality, but it is not evidence about your vial.

Tested samples and batch reports

BioXen product pages label each report by type, so you can tell what kind of evidence it is.

A report marked Laboratory analysis · Tested sample comes from an independent laboratory and records the result for the sample it received. A report marked BioXen batch report is issued for a named production batch. Where a laboratory supplies a verification link, the report card shows it, and you can check the result on the laboratory's own site.

Where no report is published for a product yet, the page says so plainly.

Warning signs

Treat a report with caution if you see any of the following:

  • No laboratory name, or a name you cannot trace to a real laboratory.
  • No test date, no batch reference or no report number.
  • Purity of exactly 100.00%. Real chromatograms almost always show minor peaks.
  • A purity figure with no method named.
  • An identity result that does not match the theoretical mass of the compound.
  • Identical numbers on reports for different products or different batches.
  • No chromatogram or spectrum where the laboratory normally supplies one.
  • A verification link that is missing, broken or points somewhere other than the laboratory.

Common questions

What does a certificate of analysis show for a peptide?
It shows what an analytical laboratory measured in a specific sample: usually the identity of the compound (by mass spectrometry), its purity (by HPLC), and sometimes the measured quantity in milligrams. It should also name the laboratory, the test date and the batch or sample tested.
Is HPLC purity the same as the amount of peptide in the vial?
No. HPLC purity is the proportion of the UV-detectable signal that belongs to the target peptide. Water, salts and counter-ions such as acetate or trifluoroacetate do not show up in that figure, so the amount of peptide in the vial is reported separately as measured content or net peptide content.
How do I know a certificate of analysis belongs to my product?
Compare the batch reference on the report with the batch on your vial label, and check that the product name and vial size match. A report for a different batch, a different strength or an unnamed sample does not describe the material you hold.
What is the difference between a third-party report and a batch report?
A third-party report is produced by an independent laboratory and describes the sample that was sent to it. A batch report is issued for a named production batch. On BioXen product pages these are labelled 'Laboratory analysis · Tested sample' and 'BioXen batch report' respectively.
What are warning signs on a certificate of analysis?
Missing laboratory name, missing test date or batch reference, a purity of exactly 100%, a mass result that does not match the compound, identical figures across different products, and no way to verify the report with the laboratory.